External Reflux Condenser

Classification Classification: Gas cooler (condenser), air cooler, high finned tubes, removable bonnet type headers.
FeaturesAir Cooler for Glycol regeneration unit for the South Pars gas fields. The cooler/condenser is used to condense the overhead vapors from the column.

External Reflux Condenser

Our client supplies glycol regeneration units for various phases of the South Pars gas fields development. In addition to a glycol reboiler steam bundle, which Robox also designed and supplied, an external reflux condenser is also required for these units.

Due to the 7 MW capacity, a bundle of nearly 12 by 4 m is required. Because of the high gas flow, a single-pass bundle was chosen with a removable bonnet type header equipped with multiple inlet nozzles. Due to the relatively low pressure, a bonnet type is very suitable for this application. Each delivery consists of 6 units. Robox designs and builds the bundles. The steelwork and impellers are provided by a subcontractor. The entire shipment was then packed seaworthy for transport to Iran. Through effective project management, Robox has successfully executed this extensive order for multiple phases.

This involves 6 Air Coolers with single-pass high finned (aluminum fins) bundles with removable bonnet type headers, type BHFB 5/12100×3775, entirely in stainless steel according to PD5500, API 661, and client specifications.