Liquid cooler/heater, Shell & Tube, Hastelloy C276, fixed tubesheets, no headers (installed directly in the piping)
Kenmerken
These heat exchangers are used in a power plant for heating saturated brine in different process stages.
In the crystallizer water cooler, hot water heats the brine. In the crystallizer condenser, steam is used.
In the crystallizer water cooler, hot water heats the brine. In the crystallizer condenser, steam is used.
Classificatie
Liquid Heaters, Shell & Tube, Fixed tube sheets with removable bonnets
Kenmerken
Fixed thermal faults and realized short delivery times
Classificatie
Condenser, Shell & Tube removable U-bundle, shell side cross (X) flow, hot water tracing on shell, removable bonnet type header.
Kenmerken
Vacuum application, very low pressure drop, large inlet and outlet nozzles, no-tubes-in-window design with impingement protection. The shell is equipped with hot water tracing at the bottom to prevent lactide accumulation inside the shell.
Classificatie
Condenser, air cooler, high finned tubes, removable cover plate type headers
Kenmerken
A customer located in the Netherlands needed a replacement bundle for an aircooler. This bundle had to be designed and built according to new applicable standards and rules. The thermal performance had to be secured while ensuring that the new unit fits into the existing shell/unit.
Classificatie
Gas cooler, Shell & Tube removable U-bundle, removable bonnet type header.
Kenmerken
Vacuum application, large volume flow, low permissible pressure loss, large entry and exit nozzles, no-tubes-in-window design with impingement protection at entry and outlet sump with level control.
For a project our customer (operating in the vacuum industry) desired gas coolers. These are assembled in a vacuum system skid that is delivered as a whole. The gas coolers provide the necessary cooling for the process gas.
For a project our customer (operating in the vacuum industry) desired gas coolers. These are assembled in a vacuum system skid that is delivered as a whole. The gas coolers provide the necessary cooling for the process gas.
Classificatie
Liquid cooler, air cooler, high finned tubes, plug type header.
Kenmerken
Produced for a terminal in the Botlek. Bottom product cooler so high viscosity. Winterization by means of louvres and steam coil to prevent wax, hydrate formation due to low temperatures in the winter.
A bottom product cooler is required for a project in a terminal in Rotterdam. This ensures the necessary cooling of the product.
A bottom product cooler is required for a project in a terminal in Rotterdam. This ensures the necessary cooling of the product.
Classificatie
Liquid Heater, Double pipe heat exchanger. Vessel. Outside electric spiral heated vessel.
Kenmerken
High pressure, high temperatures, extreme pollution and cleanability. Double pipe with removable inner tube and special high-pressure closures. Solid vessels with drilled channels, calculated with FEM analysis and equipped with special high-pressure closures.
Classificatie
Gas heat exchanger, condenser/evaporator, Shell & Tube, fixed tubesheets with integral welded bonnets.
Kenmerken
High pressure CNG heat exchangers for filling stations. Compact designs for serial application. Increased heat transfer through the use of turbulators.
Classificatie
Liquid cooler, Shell & Tube, fixed tubesheets, integral welded bonnets
Kenmerken
For a hydrogen filling station. Compact heat exchanger for cooling hydrogen under high pressure. Design pressure of 1050 barg.
Classificatie
Liquid Heater, Shell & Tube removable U-bundle. Condenser, fixed tubesheets without bonnets.
Kenmerken
Innovative project in which energy is recovered by combustion of compost.
Classificatie
Gas Heater, Shell & Tube removable U-bundle
Kenmerken
Nitrogen heater with large gas flow and low pressure loss. As a solution, a crossflow shell with several large inlet- and outlet nozzles.
Classificatie
Liquid Heater, Shell & Tube removable U-bundle
Kenmerken
Solved intensive pollution and frequent maintenance. Result lead to 200-300% better performance