Natural Gas Heater
Classificatie
Liquid /Gas heater, Shell & Tube, removable U-tube bundle, removable bonnet header, veticale opstelling
Kenmerken
A replacement gas heater is required for an existing gas pressure reducing station.
The heater works by letting hot water flow on the hull side and the natural gas through the tubes. In this case executed as a removable u-tube heat exchanger with a removable cover and in vertical arrangement.
The heater works by letting hot water flow on the hull side and the natural gas through the tubes. In this case executed as a removable u-tube heat exchanger with a removable cover and in vertical arrangement.
For an existing gas pressure reducing station, this replacement gas heater is required to compensate for the temperature drop as a result of the Joule-Thomson effect. This heater was designed and delivered by Robox in 1994. They wanted to replace the existing heater in accordance with the current legislation / regulations and standards that would fit within the existing unit.
It concerns a Shell & Tube heat exchanger. A one-pass shell with removable u-tube bundle and removable bonnet header. TEMA type BEU 273/1000 completely made of C-steel. Designed and built according to PED cat IV / Mod H1 + ASME VIII div.1 and TEMA B.