A number of heat exchangers is required for the proper functioning of this plant.
In all coolers, the process gas is cooled by means of (cooling) water or coolant. Some condensation also takes place here. Cooling medium passes through the tubes and process medium through the hull.
Because it concerns a pilot plant, various cases had to be simulated. Robox was able to provide the customer with a good support because all the knowledge and software is available in-house to reliably perform these simulations. The final customer has a significant amount of specifications regarding design, materials testing and inspection. The heat exchangers also had to be equipped with a U-stamp. Robox has combined all requirements and wishes and outsourced the U-stamp work. This process was guided by Robox, in order to support the customer. Ultimately, a package could be delivered that met all requirements and wishes.
All coolers have a single-pass shell, removable u-bundle and a removable bonnet type header, TEMA types BEU. Tubes in stainless steel 321, hulls and lids in stainless steel 321/304/316 (L). Designed and built according to PED cat. IV / Mod.G and ASME VIII Div.1 (with U-stamp), TEMA R and NACE MR 0175.