Flare-Gas Unit
Classificatie
Liquid/gas coolers. Shell & Tube, floating head with backing ring, inlet channel with removable cover.
Kenmerken
A fast track project has been started for an internaltional customer in oi and gas located in Pernis to realize a flare gas unit. Our customer has been instructed to do this in accordance with the DEP.
In these coolers, flare gas and ring liquid water are cooled by means of cooling water.
In these coolers, flare gas and ring liquid water are cooled by means of cooling water.
Due to the available time, this is a fast track project, but because the unit will be taken into use at Pernis, the DEPs must be followed.
The tubes and tubesheets must be SuperDuplex (25% Cr). Furthermore, there is Sour and very toxic service. Robox has included all these requirements in the design and also achieved a short delivery time.
Both coolers have a single-pass shell, removable bundle with floating head and backing-ring construction and a removable channel with removable cover. TEMA types AES. Tubes and tubesheets in SuperDuplex, hulls and covers in stainless steel, designed and built according to PED Cat.IV / Mod.G, ASME VIII Div.1 and TEMA R, NACE MR 0175, and SHELL DEPs.